耐電弧試驗(yàn)儀制造商 注意事項(xiàng):
1、 嚴(yán)禁試驗(yàn)主機(jī)與實(shí)驗(yàn)室的地線不接就直接開始做試驗(yàn);
2、 不要在實(shí)驗(yàn)時(shí)打開有機(jī)玻璃門;
3、 嚴(yán)禁試驗(yàn)主機(jī)電源與電腦的電源共用一個(gè);
4、 嚴(yán)禁熱插撥串口通訊線(正確操作為,關(guān)掉試驗(yàn)主機(jī)電源再拔下通 訊線);
5、 如果試驗(yàn)中有事需要離開,請(qǐng)點(diǎn)擊“結(jié)束試驗(yàn)”并按下紅色“停止按鈕”,關(guān)掉試驗(yàn)主機(jī)電源后再離開;
耐電弧試驗(yàn)儀制造商 技術(shù)參數(shù):
1、輸入電壓:交流220 V
2、輸出電壓:30KV
3、電器容量:3 KVA
4、試驗(yàn)方式:間歇電弧,連續(xù)電弧
5、試驗(yàn)電流:10MA-20MA-30MA-40MA可選
6、試驗(yàn)電壓控制誤差:≤ 1%
7、電弧通斷時(shí)間誤差: <5ms
主要適用范圍及功能:
本試驗(yàn)機(jī)是按照GB1411-2002、IPC650、IEC61621、ASTMD495設(shè)計(jì)制造,并符合JEC149、UL746A等試驗(yàn)方法。應(yīng)用于電機(jī)、電器和家用電器等行業(yè)的電工用塑料、樹脂膠和絕緣漆等絕緣材料的耐電弧性能評(píng)定。主要適用于固體絕緣材料如:塑料、薄膜、樹脂、云母、陶瓷、玻璃、絕緣油、絕緣漆、紙板等介質(zhì)的耐電弧性能測(cè)試;耐電弧試驗(yàn)機(jī)采用計(jì)算機(jī)控制,試驗(yàn)過程中可在線觀察試驗(yàn)曲線;自動(dòng)存儲(chǔ)試驗(yàn)條件及試驗(yàn)結(jié)果等數(shù)據(jù),并可存取、顯示、打印。
matters needing attention:
1. It is strictly prohibited to start the test directly without connecting the ground wire between the test host and the laboratory;
2. Do not open the organic glass door during the experiment;
3. It is strictly prohibited to share the same power supply between the test host and the computer;
4. It is strictly prohibited to hot plug and unplug the serial communication cable (the correct operation is to turn off the power of the test host and then unplug the communication cable);
5. If there is something you need to leave during the experiment, please click "End Experiment" and press the red "Stop Button". Turn off the power of the test host before leaving;
Technical parameters:
1. Input voltage: AC 220 V
2. Output voltage: 30KV
3. Electrical capacity: 3 KVA
4. Test method: intermittent arc, continuous arc
5. Test current: 10MA-20MA-30MA-40MA optional
6. Test voltage control error:≤1%
7. Arc on/off time error:<5ms
Main scope and functions:
This testing machine is designed and manufactured in accordance with GB1411-2002, IPC650, IEC61621, ASTMD495, and complies with testing methods such as JEC149 and UL746A. Assessment of arc resistance performance of electrical insulation materials such as plastics, resin adhesives, and insulating paints used in industries such as motors, appliances, and household appliances. Mainly suitable for testing the arc resistance performance of solid insulation materials such as plastic, film, resin, mica, ceramics, glass, insulation oil, insulation paint, cardboard, etc; The arc resistance testing machine adopts computer control, and the test curve can be observed online during the testing process; Automatically store experimental conditions and results data, and can access, display, and print them.
配置:
1、儀器主機(jī)1臺(tái)
2、試驗(yàn)電極1個(gè)
3、電腦1臺(tái)
4、說明書1份
5、電源線1條
6、數(shù)據(jù)線1條
7、合格證、保修卡1份
8、試驗(yàn)系統(tǒng)1套電腦內(nèi)置
操作步驟:
1、 拉開有機(jī)玻璃門,放置好電極與試樣,用測(cè)量塊測(cè)量好兩個(gè)電極之間的距離并固定住兩個(gè)電極;連接上高壓端的高壓線與低壓端的地線,連接好試驗(yàn)主機(jī)與實(shí)驗(yàn)室的接地線,關(guān)上有機(jī)玻璃門(注意:如果門沒有關(guān)好,按下試驗(yàn)按鈕不會(huì)響應(yīng));
2、 打開試驗(yàn)主機(jī)電源并預(yù)熱10—15分鐘(注意:試驗(yàn)主機(jī)與電腦的電源不能公用一個(gè)電源),初始狀態(tài)為停止按鈕上的紅色指示燈亮,試驗(yàn)按鈕上的綠色指示燈滅;打開電腦,準(zhǔn)備試驗(yàn);
3、 打開耐電弧實(shí)驗(yàn)軟件,設(shè)置試驗(yàn)參數(shù);
4、 按下“試驗(yàn)按鈕”(綠色指示燈亮,紅色指示燈滅),點(diǎn)擊“10mA 1/8通7/8段”(即階段1),當(dāng)60s后自動(dòng)停止高壓(注意:綠色指示燈是亮的,試驗(yàn)時(shí)間不可更改不要拉開有機(jī)玻璃門),再點(diǎn)擊“10mA 1/4通3/4段”(即階段2),當(dāng)60s后自動(dòng)停止高壓,再點(diǎn)擊“10mA 1/4通1/4段”(即階段3),當(dāng)60s后自動(dòng)停止高壓,再點(diǎn)擊“10mA連續(xù)”(即階段4),當(dāng)60s后自動(dòng)停止高壓;再點(diǎn)擊“20mA連續(xù)”(即階段5),每個(gè)實(shí)驗(yàn)階段的試驗(yàn)時(shí)間為60s,60s后如果試樣沒有擊穿,接在點(diǎn)擊“30 mA連續(xù)”(即階段6)如果60s后沒有擊穿,再點(diǎn)擊“40 mA連續(xù)”(即階段7)60s后停止,按下“停止按鈕”(綠色指示燈滅,紅色指示燈亮);
如果試樣在某個(gè)階段被擊穿,這時(shí)實(shí)驗(yàn)人員需要點(diǎn)擊“結(jié)束試驗(yàn)”,并按下“停止按鈕”(綠色指示燈滅,紅色指示燈亮)來停止試驗(yàn),拉開有機(jī)玻璃門更換試樣,重復(fù)上述步驟試驗(yàn);
5、 一組試驗(yàn)為5次,做完一組實(shí)驗(yàn)后如需保存請(qǐng)點(diǎn)擊“保存文件”,保存后再點(diǎn)擊“下組實(shí)驗(yàn)”接著做下一組;
to configure:
1. 1 instrument host
2. 1 test electrode
3. 1 computer
4. 1 instruction manual
5. 1 power cord
6. 1 data cable
7. 1 copy of certificate of conformity and warranty card
8. 1 set of testing system with built-in computer
Operation steps:
1. Open the organic glass door, place the electrodes and the sample, use a measuring block to measure the distance between the two electrodes and fix them in place; Connect the high-voltage wire and low-voltage wire of the high-voltage end, connect the grounding wire of the test host to the laboratory, and close the organic glass door (note: if the door is not closed properly, pressing the test button will not respond);
2. Turn on the power supply of the test host and preheat for 10-15 minutes (note: the power supply of the test host and computer cannot share the same power supply). The initial state is that the red indicator light on the stop button is on, and the green indicator light on the test button is off; Turn on the computer and prepare for the experiment;
3. Open the arc resistance test software and set the test parameters;
4. Press the "Test button" (green indicator light on, red indicator light off), click "10mA 1/8 on 7/8 section" (i.e. Stage 1), automatically stop the high voltage after 60 seconds (note: the green indicator light is on, the test time cannot be changed, do not open the organic glass door), then click "10mA 1/4 on 3/4 section" (i.e. Stage 2), automatically stop the high voltage after 60 seconds, click "10mA 1/4 on 1/4 section" (i.e. Stage 3), automatically stop the high voltage after 60 seconds, click "10mA continuous" (i.e. Stage 4), automatically stop the high voltage after 60 seconds; Click "20mA continuous" again (i.e. stage 5), and the test time for each experimental stage is 60 seconds. If the sample does not break down after 60 seconds, click "30 mA continuous" (i.e. stage 6). If there is no breakdown after 60 seconds, click "40 mA continuous" (i.e. stage 7) and stop after 60 seconds. Press the "stop button" (green indicator light off, red indicator light on);
If the sample is broken down at a certain stage, the experimenter needs to click "End Test" and press the "Stop Button" (green indicator light off, red indicator light on) to stop the test, open the organic glass door to replace the sample, and repeat the above steps of the test;
5. A set of experiments is 5 times. After completing one set of experiments, if you need to save it, please click "Save File". After saving, click "Next Group Experiment" to continue with the next set;
公司承諾:
1.購機(jī)前,我們專門派技術(shù)人員為您設(shè)計(jì)的流程和方案
2.購機(jī)后,將免費(fèi)指派技術(shù)人員為您調(diào)試安裝
3.整機(jī)保修一年,產(chǎn)品終身維護(hù)
4.常年供應(yīng)設(shè)備的易損件及耗品確保儀器能長(zhǎng)期使用
5、售后管理:我公司實(shí)現(xiàn)計(jì)算機(jī)化管理,實(shí)行客戶定期電話回訪制度,定期復(fù)查設(shè)備的工作情況,定期電話指導(dǎo)用戶對(duì)設(shè)備進(jìn)行保養(yǎng)和檢測(cè),以便設(shè)備正常運(yùn)轉(zhuǎn),跟蹤客戶的設(shè)備使用情況,以便及時(shí)對(duì)設(shè)備進(jìn)行維護(hù)
6、物流情況:及時(shí)提供貨源,確保全國范圍內(nèi)2-10內(nèi)到貨,持續(xù)穩(wěn)定地為代理商做全面服務(wù)工作,提供合理的運(yùn)作空間。公司有專業(yè)的技術(shù)人員為您安裝指導(dǎo)。
7、軟件升級(jí):終生免費(fèi)提供新版本控制軟件。
8、安裝培訓(xùn):儀器包裝內(nèi)附有說明書,專業(yè)培訓(xùn)人員為客戶指定操作者講解儀器正常操作流程、操作注意事項(xiàng)及儀器的日常維護(hù)要求;也可以根據(jù)客戶要求提供上門培訓(xùn)服務(wù)。
業(yè)務(wù)咨詢:932174181 媒體合作:2279387437 24小時(shí)服務(wù)熱線:15136468001 盤古機(jī)械網(wǎng) - 全面、科學(xué)的機(jī)械行業(yè)免費(fèi)發(fā)布信息網(wǎng)站 Copyright 2017 PGJXO.COM 豫ICP備12019803號(hào)